Select a section
- CWC LowFriction UL Type XHHW-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications in accordance with the NEC. The conductor is suitable for use in dry or wet locations at temperatures not to exceed 90°C. The conductor is rated 600 V / 1000 V. Although this product may be installed without the application of pulling lubricant, a good quality pulling lubricant is recommended.
- Conductor:
- Annealed compact stranded AA-8000 series Aluminum Conductor Material (ACM).
- Insulation:
- Low coefficient of friction, abrasion, moisture, and heat resistant colored crosslinked polyethylene (XLPE).
- Overall Diameter Less than or Equal to 1.000 in
- Not Under Tension: 4x outer diameter
- Under Tension (During Pull): 6x outer diameter
- Overall Diameter Greater than 1.000 in
- Not Under Tension: 5x outer diameter
- Under Tension (During Pull): 7.5x outer diameter
- Sizes 6 AWG and larger marked FT2
- Sizes 6 AWG and larger in all colors sunlight resistant and marked
- Sizes 1/0 AWG and larger marked ''FOR CT USE''
- RoHS Compliant
- ASTM B800 -- 8000 Series Aluminum Alloy Wire for Electrical Purposes—Annealed and Intermediate Tempers
- ASTM B801 -- Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
- UL 44 -- Thermoset-Insulated Wires and Cables
- ICEA S-95-658 / NEMA WC70 -- Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- Federal Specification AA-59544
- Federal Specification JC-30B
- UL listed as Type XHHW-2 -- File E487972
- 250 ft reel
- 500 ft reel
- 1000 ft reel
- Master reel
- Coil
Cable Layers.1326.1 XHHW Red